Open Access


Read more
image01

Online Manuscript Submission


Read more
image01

Submitted Manuscript Trail


Read more
image01

Online Payment


Read more
image01

Online Subscription


Read more
image01

Email Alert



Read more
image01

Original Research Article | OPEN ACCESS

Determination of theobromine and caffeine in some Malaysian beverages by liquid chromatography-time-of-flight mass spectrometry

Fouad F Al-Qaim1,2 , Ali Yuzir1, Zainab H Mussa1,3

1Malaysia-Japan International Institute of Technology (MJIIT) Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100 Kuala Lumpur, Malaysia; 2Department of Chemistry, Faculty of Sciences for Women, University of Babylon, Iraq; 3School of Chemical Sciences and Food Technology, Faculty of Science and Technology, National University of Malaysia (UKM), 43600 Bangi, Selangor, Malaysia.

For correspondence:-  Fouad Al-Qaim   Email: fouadalkaim@yahoo.com   Tel:+60173394821

Accepted: 24 February 2018        Published: 31 March 2018

Citation: Al-Qaim FF, Yuzir A, Mussa ZH. Determination of theobromine and caffeine in some Malaysian beverages by liquid chromatography-time-of-flight mass spectrometry. Trop J Pharm Res 2018; 17(3):529-535 doi: 10.4314/tjpr.v17i3.20

© 2018 The authors.
This is an Open Access article that uses a funding model which does not charge readers or their institutions for access and distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0) and the Budapest Open Access Initiative (http://www.budapestopenaccessinitiative.org/read), which permit unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited..

Abstract

Purpose: To determine the concentration of theobromine (TB) and caffeine (CF) in tea and other beverages using liquid chromatography-time of flight-mass spectrometry (LC-TOF-MS).
Methods: The extract of caffeine and theobromine from tea and other beverages was filtered by 0.45 μm nylon micro-syringe and then injected into a LC-ToF-MS system. Theobromine and caffeine were separated using Thermo Scientific C18-column (length 250 mm, width 2.1 mm and diameter 5 μm). Acetonitrile-methanol (ACN – MeOH, 3:1 v/v) was used as mobile phase B, while mobile phase A was 0.1 % FA in DIW. The volume injected was 30 μL at a rate of 0.3 mL/min.
Results: Good linearity was obtained in the range of 0.3 – 400 and 0.2 – 200 mg/L for theobromine and caffeine, respectively (regression coefficient (R2) > 0.970). The limits of detection were 0.15 and 0.05 μg/mL for theobromine and caffeine, respectively. The highest concentrations of caffeine and theobromine determined in tea samples were 159.1 and 255.8 mg/L, respectively. 
Conclusion: Theobromine and caffeine have been successfully analysed in tea, coffee and soft drinks. LC-TOF-MS is an accurate and promising instrument for the determination of the studied compounds in beverages

Keywords: Theobromine, Caffeine, Tea, Coffee, LC-TOF/MS

Impact Factor
Thompson Reuters (ISI): 0.523 (2021)
H-5 index (Google Scholar): 39 (2021)

Article Tools

Share this article with



Article status: Free
Fulltext in PDF
Similar articles in Google
Similar article in this Journal:

Archives

2024; 23: 
1,   2,   3
2023; 22: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2022; 21: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2021; 20: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2020; 19: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2019; 18: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2018; 17: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2017; 16: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2016; 15: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2015; 14: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2014; 13: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2013; 12: 
1,   2,   3,   4,   5,   6
2012; 11: 
1,   2,   3,   4,   5,   6
2011; 10: 
1,   2,   3,   4,   5,   6
2010; 9: 
1,   2,   3,   4,   5,   6
2009; 8: 
1,   2,   3,   4,   5,   6
2008; 7: 
1,   2,   3,   4
2007; 6: 
1,   2,   3,   4
2006; 5: 
1,   2
2005; 4: 
1,   2
2004; 3: 
1
2003; 2: 
1,   2
2002; 1: 
1,   2

News Updates